Greenhouse Heater BTU Calculator

This calculator estimates how much heat your greenhouse loses on its coldest night, so you know the heater output to look for before you compare models. Enter the size, the covering and two temperatures. The result is in BTU per hour, the unit on propane and gas heater listings, and in watts, the unit on electric heater listings.

Turn on JavaScript to use the calculator. The formula and a worked example are below, so you can also work it out by hand.

How the calculator works

A heater has to replace the heat the greenhouse loses. Heat leaves in two ways: through the covering, and through air that leaks in around doors, vents and panel joints. The calculator adds the two and puts a 10% margin on top.

Heat lost through the covering: Q = U × A × ΔT

  • U is the U-value of the covering: how many BTU per hour pass through one square foot for every degree Fahrenheit of difference between inside and outside. Lower is better.
  • A is the covered surface in square feet: side walls, end walls and roof. The floor is not counted.
  • ΔT is the inside temperature you want to hold minus the coldest outside temperature.

Heat lost to air leaks: 0.02 × volume × air changes per hour × ΔT. Volume is in cubic feet. The 0.02 factor is Manitoba Agriculture’s figure of 0.373 watts per cubic meter per °C per air change, converted to BTU per hour, cubic feet and °F.

Safety margin: Manitoba Agriculture suggests adding 10% to the total heat loss, and the calculator does that for you.

Watts: one watt of electric heat equals 3.412 BTU per hour, so the calculator divides the BTU result by 3.412.

U-values used for each covering

Covering U-value Source
Single-layer polyethylene film 1.2 Purdue University
Double-layer inflated polyethylene film 0.70 Purdue University
Double (twin-wall) polycarbonate 0.55 Purdue University
Twin-wall polycarbonate, thin 4 mm hobby panels 0.70 Greenhouse maker figure
Single-pane glass 1.1 Greenhouse maker figures, which run from about 1.05 to 1.13

All values are in BTU per hour per square foot per °F. Purdue gives the first three. For thin hobby panels and single glass we found no university figure, so we use what greenhouse makers publish and label it that way. If your panel or film maker lists a U-value, pick “I know my U-value” and enter it.

Worked example

A hoop house 10 feet wide and 12 feet long, covered in double-layer inflated poly. You want to hold 50°F inside, and the coldest night is 20°F.

  • Covered surface: the curved roof is 12 × π × 5 = 188.5 sq ft and the two half-circle ends are π × 5² = 78.5 sq ft, so 267 sq ft in total.
  • Volume: π × 5² ÷ 2 × 12 = 471 cubic feet.
  • ΔT: 50 − 20 = 30°F.
  • Through the covering: 0.70 × 267 × 30 = 5,608 BTU/hr.
  • Air leaks at 0.25 air changes per hour: 0.02 × 471 × 0.25 × 30 = 71 BTU/hr.
  • Subtotal 5,678 BTU/hr, plus 10% (568) = 6,246 BTU/hr, or about 1,831 watts.

That is more than one 1,500-watt plug-in heater can deliver (about 5,100 BTU/hr). For that night you would need a second electric heater on its own circuit, or a fuel-burning heater rated above 6,246 BTU/hr. Dropping the target to 40°F cuts ΔT to 20°F and the result to about 4,160 BTU/hr, which a single 1,500-watt heater covers.

Using the number when you shop

  • Electric heaters list watts. Most plug-in models top out at 1,500 watts on a standard 120-volt outlet, so above about 5,100 BTU/hr you need more than one heater or a different fuel.
  • Propane, natural gas, kerosene and diesel heaters list BTU per hour. Pick one rated at or above your result, and check the manual for the fresh-air ventilation it needs inside a closed greenhouse.
  • A thermostat lets a heater sized for the coldest night idle on milder ones instead of overheating the house.
  • Cutting heat loss lowers the number you need: a second layer of film or bubble insulation lowers U, and sealing gaps lowers air changes. Run the calculator again with the new values to see the difference.

Questions

What temperature should I keep a greenhouse at in winter?

That depends on what you grow. Holding just above freezing protects hardy plants, while seedlings and warm-season crops need more. Enter the lowest temperature your plants can take, since every degree you add raises the heater size.

Which outside temperature should I enter?

Use the coldest night you expect in the season you plan to heat, not the average low. A heater sized for an average night falls short on the nights that matter.

Why is my result higher than a “watts per square foot of floor” rule of thumb?

Floor-area rules ignore the walls, the roof height, the covering and how cold it gets where you live. This calculator works from the covered surface and your own temperatures, so a tall greenhouse with single glass in a cold area comes out higher than a floor rule suggests.

Does the calculator count heat from the ground or the sun?

No. It sizes for a cold, still night with no sun, which is when a heater has to carry the load. It also leaves out heat lost through the base and through cracks or holes, so a drafty or damaged greenhouse needs more heat than the result shows.

Is a bigger heater always better?

Not by much. Some headroom over the result is useful, and the 10% margin already gives you that. A heater far larger than the result costs more to buy, and fuel models can need more ventilation. A thermostat matters more than extra size.

Sources

  • Alex Miller and Krishna Nemali, “Calculating Greenhouse Heating Requirements“, Purdue University Controlled Environment Agriculture, March 2019: formula Q = U × A × ΔT and the U-values for single poly, double poly and double polycarbonate.
  • Manitoba Agriculture, “Greenhouse Heating and Venting“: the air exchange term, 0.25 air changes per hour for a new double-poly house, and the 10% margin.
  • Greenhouse maker spec pages for single glass and 4 mm twin-wall polycarbonate.